I received a CED M2 for XMAS and finally got it to the range today. It took my XDm 9mm, 4.5...
The M2 was so easy to set and use it amazed me.. Can't wait to go again..
It hooked straight to my computer with Windows 7
I did a couple of strings..
The first was with was with Federal 115g FMJ RN...
After I finished with the chrony I finished the box of 45... No FTE or any other problems..
String 1
_ 1)_1169.0_ -6.2
_ 2)_1179.0_ 3.8
_ 3)_1174.0_ -1.2
_ 4)_1185.0_ 9.8
_ 5)_1169.0_ -6.2
__ High:_1185.0
__ Low:_1169.0
__ E.S.:_ 16.0
__ Ave.:_1175.2
__ S.D.:_ 6.1
__ 95%:_ ±9.6
String 2 was with my reloads..CCI 500 primers, 4.1 Titegroup, MG 124 CMJ, OAL 1.145... I had sever FTE and a couple that did not chamber correctly
String 2
_ 1)_1109.0_ 26.0
_ 2)_1087.0_ 4.0
_ 3)_1095.0_ 12.0
_ 4)_1092.0_ 9.0
_ 5)_1121.0_ 38.0
_ 6)_1103.0_ 20.0
_ 7)_1106.0_ 23.0
_ 8)_1099.0_ 16.0
_ 9)_1105.0_ 22.0
_ 10)_1102.0_ 19.0
_ 11)_1066.0_ -17.0
_ 12)_1088.0_ 5.0
_ 13)_1046.0_ -37.0
_ 14)_1071.0_ -12.0
_ 15)_1071.0_ -12.0
_ 16)_1050.0_ -33.0
_ 17)_1072.0_ -11.0
_ 18)_1047.0_ -36.0
_ 19)_1060.0_ -23.0
_ 20)_1070.0_ -13.0
__ High:_1121.0
__ Low:_1046.0
__ E.S.:_ 75.0
__ Ave.:_1083.0
__ S.D.:_ 21.9
__ 95%:_ ±10.8
Now I need a little help..
I need to make some adjustments before I go again... Should I increase the load to 4.3 (4.4 is max per my data) or try to bring the OAL to say 1.2 to cure the FTE problem???
Also, how do you compute the Power Factor??
Thanks for any input..
God I love this stuff!!
The M2 was so easy to set and use it amazed me.. Can't wait to go again..
It hooked straight to my computer with Windows 7
I did a couple of strings..
The first was with was with Federal 115g FMJ RN...
After I finished with the chrony I finished the box of 45... No FTE or any other problems..
String 1
_ 1)_1169.0_ -6.2
_ 2)_1179.0_ 3.8
_ 3)_1174.0_ -1.2
_ 4)_1185.0_ 9.8
_ 5)_1169.0_ -6.2
__ High:_1185.0
__ Low:_1169.0
__ E.S.:_ 16.0
__ Ave.:_1175.2
__ S.D.:_ 6.1
__ 95%:_ ±9.6
String 2 was with my reloads..CCI 500 primers, 4.1 Titegroup, MG 124 CMJ, OAL 1.145... I had sever FTE and a couple that did not chamber correctly
String 2
_ 1)_1109.0_ 26.0
_ 2)_1087.0_ 4.0
_ 3)_1095.0_ 12.0
_ 4)_1092.0_ 9.0
_ 5)_1121.0_ 38.0
_ 6)_1103.0_ 20.0
_ 7)_1106.0_ 23.0
_ 8)_1099.0_ 16.0
_ 9)_1105.0_ 22.0
_ 10)_1102.0_ 19.0
_ 11)_1066.0_ -17.0
_ 12)_1088.0_ 5.0
_ 13)_1046.0_ -37.0
_ 14)_1071.0_ -12.0
_ 15)_1071.0_ -12.0
_ 16)_1050.0_ -33.0
_ 17)_1072.0_ -11.0
_ 18)_1047.0_ -36.0
_ 19)_1060.0_ -23.0
_ 20)_1070.0_ -13.0
__ High:_1121.0
__ Low:_1046.0
__ E.S.:_ 75.0
__ Ave.:_1083.0
__ S.D.:_ 21.9
__ 95%:_ ±10.8
Now I need a little help..
I need to make some adjustments before I go again... Should I increase the load to 4.3 (4.4 is max per my data) or try to bring the OAL to say 1.2 to cure the FTE problem???
Also, how do you compute the Power Factor??
Thanks for any input..
God I love this stuff!!