New RCBS Uniflo corrosion

Status
Not open for further replies.

modlaw

Member
Joined
Aug 27, 2014
Messages
36
Location
Indiana
Has anyone ever experienced corrosion in their Uniflow powder measure? I don't mean a little; I mean chunks with one 2" long. I started having trouble throwing accurate measures, so I took it apart. First, This was a Christmas present. And, no I don't leave powder stored in the measure. I have loaded about 300 rds with it. and empty it every time. The last 2 1/2 inches of the drop had large chunks of corrosion inside. I tapped it on the bench and probably a quarter cup of rust came out. Now, the last 2 1/2" looks totally pitted and brown. I am also wondering if flakes of corrosion got into my newly loaded rounds and what effect it would have on my gun.
 
What kind of "corrosion"? Rust? That would come from the barrel but other than that I can't imagine what kind of corrosion you could be seeing. I believe the body is cast zinc and that will corrode but that would be pretty obvious looking down the tube.

If it's rust, yes it could have certainly gotten into your ammo. Pull that ammo down. I would disassemble the measure and determine what is happening. The only way rust like that could have happened is for a lot of water to have gotten into the barrel or drop tube. Is it new? Contact RCBS if so.

Short, we need more information.
 
I have one that is very, very old. It came with the 2 rotors. The metering screw had some surface rust when I got it I cleaned it off with a wire brush, never to return. The rotors are metal but never had any rust.

Some thin does not sound right, as mentioned more info is needed or pictures??
 
Clean it up with a rotory wire brush, and alcohol, and when it's clean and lookin purty again, get you some paste wax like Johnson's, and wax it up good.....let it dry and buff.

Wax it again once a month or so and you should be good. Indiana must be humid this year. BTW, waxing is the secret to making it throw more accurately as well....that and a baffle.
 
Last edited:
It's probably made in China--if so--there is your problem
I have one 35/40 years old---never a bit of problems after thousands of rounds
 
Well, first of all. yes it is corrosion. I can't see it could be anything else. The biggest piece was shaped with the contour of the drop chute. Wire brush/wax? Imagine an old metal fence post standing in a field about 20 years. That is what this last 2 1/2" looks like now. It would be very difficult to get any wire brush to the problem since the plastic hopper is permanently attached and the drop hole is small. I wish it were possible to take a picture of the problem. I am going to phone RCBS Monday and talk to them. I just assembled and started to use it this spring.
 
Has anyone ever experienced corrosion in their Uniflow powder measure? I don't mean a little; I mean chunks with one 2" long.

Sounds more like to me the powder is breaking down because of some kind of chemical reaction to something on the surface and resembling rust. A quarter cup of rust would mean you've lost a quarter cup or more of metal. Ain't much more than that on the whole Uniflow. As others have said, pics would help.
 
Sounds like old powder left in the measure. No way you'll get 1/4 cup of rust to shake out of a uniflow.
 
Did you clean the measure out before using it.?? Let RCBS deal with it.

The Hopper IS NOT meant to be taken off, you will probably crack it. Look at the video closely in the beginning. It is for REPLACING a broken one.

The correct video. "If it is cracked or destroyed"

http://www.youtube.com/watch?v=5EF_aPMj6sY
 
I'm curious to see this rust that came out. A 2"+ piece? Ya sure it wasn't from a mud dauber?
Things packed away in garages can tend to get all sorts of critters calling it a new home.
 
The first thing I noticed, the first time I saw the video, is that he removed a new hopper quite easily and merely remounted the same hopper.

I removed my hoppers on all three of mine and used a drill, wire brush, and a grinding stone.....then a sanding disk.....smoothed them all good then waxed. Hoppers went back on fine with no breakage. They repeat drops much better.
 
I'm going to try to get a pic this afternoon. I will post what I come up with. I am also going to dig through the trash to see if I can fine a piece of this stuff. Thanks.
 
I'll admit it sure don't' look like powder buildup that was left behind.

I see what appears to be green paint on the pieces?
Could this be some kind of casting "slag" from the factory that wasn't cleaned off?
Either way I'd contact rcbs. Theyll make it right.
 
As per the instructions did you clean all internal parts to remove any factory oils and assembly residue??
 
Looks like the drop tube was partially plugged and powder was trapped.

Whatever the cause, RCBS will probably send a whole new measure. If they say they will send a new body, tell them you're not sure you can get the plastic cylinder off. Since they don't want a dissatisfied customer....
 
Update

Just talked to RCBS. They said sometimes in the casting process, the sand will adhere to the inside of the chute and there will be improper cleaning after that process. He said he has seen a couple come in like that. Normal consumer cleaning will not clear the melted sand away. Anyway, they are sending a new unit with hopper attached plus a new measuring screw. Great customer service. I am going to wax the inside as suggested.
 
Status
Not open for further replies.
Back
Top